Dr. R Pulliam, M.D.
What this data tells you about Dr. Pulliam
Dr. R Pulliam is a cardiovascular disease specialist in Lancaster, PA, with 20 years of NPI registration. Based on federal Medicare data, Dr. Pulliam performed 4,364 Medicare services across 3,548 unique beneficiaries.
Between the years covered by Open Payments, Dr. Pulliam received a total of $8,824 from 13 pharmaceutical and/or device companies across 90 individual payments. These payments are legal, publicly disclosed under the federal Sunshine Act, and common in cardiovascular disease. Most payments are for meals and travel — low-value interactions common across virtually all practicing physicians. Patients may wish to discuss these relationships with their provider.
The Data Coverage level for Dr. Pulliam is Very High — reflecting how much public federal data is available about this provider. Patients are encouraged to use this data as one of several factors when choosing a healthcare provider.
Medicare Practice Summary
Medicare Utilization ↗Top procedures by volume
Ranked by number of services performed for Medicare patients. Avg. submitted charge is what the provider billed; avg. Medicare payment is what CMS paid.
| Procedure | Volume | Avg. paid | Avg. submitted |
|---|---|---|---|
| Remote pacemaker/defibrillator monitoring, 90 days Remote evaluation of a pacemaker or implantable defibrillator system within 90 days of the last check. |
999 | $15 | $50 |
| Remote pacemaker monitoring, 90 days Remote assessment of a pacemaker system, including single, dual, multiple lead, or leadless devices, performed up to 90 days apart. |
760 | $20 | $68 |
| Office visit, established patient (30-39 min) A follow-up office visit for an existing patient lasting between 30 and 39 minutes. The visit involves medical evaluation and management of the patient's condition. |
370 | $84 | $237 |
| Remote cardiac rhythm monitor evaluation, up to 30 days Review and analysis of data from a remote cardiac rhythm monitoring system over a period of up to 30 days. |
292 | $19 | $54 |
| Remote monitoring of implantable heart rhythm device Evaluation of data transmitted remotely from an implantable cardiovascular monitor, such as a loop recorder or subcutaneous cardiac rhythm monitor, over a period up to 30 days. |
292 | $27 | $86 |
| Remote evaluation of implantable defibrillator system Remote assessment of a single, dual, or multiple lead implantable defibrillator system within 90 days of the previous evaluation. |
246 | $26 | $134 |
| Continuous EKG monitoring review, 48-7 days Review and interpretation of continuous external EKG recordings lasting more than 48 hours up to 7 days. |
244 | $17 | $45 |
| Pacemaker programming, dual lead system Adjustment and configuration of a dual-lead pacemaker device to ensure proper operation and settings. |
239 | $57 | $114 |
| New patient office visit (45-59 min) An initial office visit for a new patient lasting between 45 and 59 minutes. This code covers the total time spent by the physician or qualified healthcare professional on the date of the encounter. |
118 | $111 | $324 |
| Pacemaker system programming Adjustment and configuration of a pacemaker device to ensure proper operation. This service involves setting device parameters before or after surgical implantation. |
109 | $11 | $32 |
| 2-day continuous ECG with professional review A two-day continuous electrocardiogram recording that includes a review by a healthcare professional. |
60 | $12 | $81 |
| Atrial fibrillation ablation with pulmonary vein isolation A procedure to treat atrial fibrillation by mapping the heart's electrical activity and destroying tissue causing irregular contractions. This is done by isolating the pulmonary veins using catheter-based destruction. |
52 | $710 | $2,203 |
| Pacemaker insertion with heart chamber electrodes A surgical procedure to implant a pacemaker device and place electrodes into the upper and lower chambers of the heart to regulate heart rhythm. |
45 | $307 | $1,608 |
| Heart conduction tissue destruction A procedure that destroys heart conduction tissue to create a heart block. |
41 | $427 | $1,824 |
| Hospital follow-up visit, moderate complexity Follow-up hospital visit for an existing patient involving moderate medical decision making. The visit requires at least 35 minutes of time spent on the date of service. |
37 | $61 | $142 |
| Programming of dual lead implantable defibrillator system Adjustment and testing of the settings for an implanted heart device with two leads to ensure proper function. |
35 | $58 | $160 |
| Programming of multiple lead implantable defibrillator system Adjustment and testing of the settings for an implanted heart device with multiple leads to ensure proper function. |
32 | $80 | $174 |
| Insertion of implantable heart rhythm monitor A small device is placed under the skin to continuously record the heart's electrical activity. This helps detect irregular heart rhythms that may not appear during a standard office visit. |
31 | $63 | $230 |
| Pacemaker programming, single lead Adjustment and testing of a single-lead pacemaker to ensure it functions correctly. |
31 | $50 | $98 |
| Continuous ECG monitoring, up to 30 days Continuous heart rhythm monitoring for up to 30 days, including professional review and reporting of the results. |
29 | $19 | $81 |
| Implantable defibrillator programming Adjustment and configuration of an implanted heart rhythm device before or after surgery. |
29 | $17 | $46 |
| Pacemaker system evaluation Assessment of a pacemaker device, including single, dual, multiple lead, or leadless systems. |
29 | $15 | $42 |
| Radiofrequency ablation for supraventricular tachycardia A procedure to locate and destroy abnormal heart tissue in the upper chambers of the heart that causes a rapid heart rate. |
29 | $628 | $1,642 |
| External EKG monitoring, 8-15 days Continuous external electrocardiogram recording and review over a period of 8 to 15 days to monitor heart rhythm. |
27 | $19 | $50 |
| Catheter ablation for abnormal heart rhythm A procedure where catheters are inserted to destroy tissue causing irregular heartbeats. |
24 | $233 | $1,281 |
| Pacemaker and lower heart chamber electrode insertion A surgical procedure to implant a pacemaker device and place an electrode in the lower chamber of the heart to help regulate the heartbeat. |
18 | $261 | $1,485 |
| Pacemaker system programming Adjustment and testing of a multi-lead pacemaker to ensure proper function and settings. |
17 | $52 | $132 |
| Implantable defibrillator system check A check of the implanted defibrillator device to ensure it is functioning correctly. This evaluation covers single, dual, or multiple lead systems. |
17 | $28 | $92 |
| Initial hospital admission, moderate complexity Initial hospital inpatient or observation care for a new patient involving moderate-level medical decision making, with at least 55 minutes total time on the date of the encounter. |
17 | $100 | $274 |
| Heart rhythm stimulator programming after drug infusion Adjustment of a heart rhythm stimulation device following a drug infusion. This procedure involves reprogramming the device settings to ensure proper function after the medication has been administered. |
16 | $62 | $477 |
| Echocardiogram with color Doppler An ultrasound of the heart that uses color imaging to visualize blood flow, measure flow rate, and assess valve function. |
15 | $2 | $12 |
| Echocardiogram, transthoracic An ultrasound of the heart that uses color to show blood flow, rate, direction, and valve function. |
14 | $52 | $192 |
| Transesophageal echocardiogram An ultrasound of the heart performed using a probe inserted into the esophagus to obtain detailed images of heart structures and function. |
14 | $76 | $315 |
| Removal and replacement of dual lead permanent pacemaker This procedure involves removing an existing permanent pacemaker with two leads and replacing it with a new device. It is performed to update or repair the heart rhythm management system. |
13 | $264 | $1,104 |
| Programming of single lead implantable defibrillator system Adjustment and testing of the settings for a single-lead implantable cardioverter-defibrillator (ICD) to ensure proper function. |
12 | $55 | $122 |
| Insertion of implantable defibrillator system A surgical procedure to place an implantable cardioverter-defibrillator (ICD) device into the body. The device is connected to the heart to monitor heart rhythm and deliver shocks if dangerous arrhythmias occur. |
11 | $647 | $2,790 |
Industry Payment Transparency
Open Payments through 2024 ↗Payment profile
Industry payments classified by relationship type. Not all payments are equal — research and consulting reflect different relationships than speaking programs or meals.
Payment trend by year
Annual totals from pharmaceutical and medical device companies.
Payments by company (2024)
All-time payments by company (2018-2024) ›
Associated products mentioned in payments ›
Most payments (100%) are for meals and travel — low-value interactions that are common across virtually all practicing physicians.
Geographic Context
0.0 mi
Data Sources
| Provider Registry | ✓ NPPES | Weekly updates |
| Medicare Enrollment | ✓ PECOS | Monthly updates |
| Practice Data | ✓ Medicare Util. | Annual (CY lag) |
| Industry Payments | ✓ Open Payments | CY 2024 |
| Disciplinary History | — Not public | N/A |
This provider has data in 4 of 4 available federal datasets, with a Data Coverage level of Very High. This reflects how much public data is available about a provider. How we calculate this →
Summary
Dr. Pulliam is a remote & electrophysiology specialist, with above-average Medicare volume (top 11% in PA), with low-engagement industry engagement, with 20 years of NPI registration.
This summary is auto-generated from federal data, describing data availability and patterns. Read our methodology →
Frequently Asked Questions
Is Dr. Pulliam experienced with remote pacemaker/defibrillator monitoring, 90 days?
Does Dr. Pulliam receive payments from pharmaceutical companies?
How do Dr. Pulliam's costs compare to other cardiologists in Lancaster?
What does Data Coverage mean?
Is this data up to date?
Explore related providers
All data on this page is sourced verbatim from public federal records published by the U.S. Centers for Medicare & Medicaid Services (CMS): NPPES ↗, Open Payments ↗, Medicare Provider Utilization ↗, and PECOS. Publication is mandated by the Physician Payments Sunshine Act (§6002 ACA, 42 U.S.C. §1320a-7h) and the Freedom of Information Act.
This page is not medical advice, an endorsement, a recommendation, or a quality rating. Data Coverage reflects data completeness — how much federal information exists for this provider — not clinical performance, patient outcomes, or quality of care. Always verify information directly with the provider and consult a licensed clinician before making medical decisions.
Provider corrections: Provider portal · Privacy questions: Privacy Policy · Terms: Terms of Use · Methodology: Methodology